[MIP-523] μˆ˜λ™νŽ˜μΌμ˜€λ²„ μ‹œ Mirror Diskκ°€ νŽ˜μΌμ˜€λ²„ λ˜μ§€ μ•ŠλŠ” ν˜„μƒ

Subject
μˆ˜λ™νŽ˜μΌμ˜€λ²„ μ‹œ Mirror Diskκ°€ νŽ˜μΌμ˜€λ²„ λ˜μ§€ μ•ŠλŠ” ν˜„μƒ


APPLIES TO:
MCCS version: 3.2, Windows 7 Professional K x86, MCCS 3.2(2011.12.13, r96111), DK(7.3.1)



SYMPTOMS
μˆ˜λ™νŽ˜μΌμ˜€λ²„ λͺ…령이 μ‹œμž‘λ˜λ©΄ Activeμ„œλ²„μ—μ„œλŠ” Mirror_D λ¦¬μ†ŒμŠ€κ°€ detachλ˜μ§€λ§Œ, Standbyμ„œλ²„μ—μ„œλŠ” attachκ°€ λ˜μ§€ μ•ŠμŒ



CAUSE
"emcmdλͺ…λ Ήμ–΄λ‘œ switchoverλ₯Ό μ‹œλ„ν–ˆμœΌλ‚˜ μ—λŸ¬μ½”λ“œ 54λ₯Ό λ°˜ν™˜ν•˜κ³  switchover μ‹€νŒ¨
net helpmsg 54κ²°κ³Ό ""λ„€νŠΈμ›Œν¬λ₯Ό μ‚¬μš© μ€‘μž…λ‹ˆλ‹€"" λΌλŠ” 문ꡬ 좜λ ₯됨
Network busy의 원인 규λͺ…이 λ˜μ§€ μ•ŠμŒ.
"



SOLUTION
"UNC μ΄λ¦„μœΌλ‘œ 접근이 λΆˆκ°€ν•œ 상황인데 UNC 둜 μ ‘κ·Όν•˜λŠ” 것은 DK κ΅¬μ„±μ‹œμ— λ°˜λ“œμ‹œ μ„ ν–‰λ˜μ–΄μ•Ό 함
λ”°λΌμ„œ UNC μ΄λ¦„μœΌλ‘œ 접근후에 μ—‘μ„ΈμŠ€κ°€ μ•ˆ 될 경우 μž¬λΆ€νŒ…μ„ ν•˜λŠ” κ²ƒμœΌλ‘œ 절차λ₯Ό μ •ν•˜κ³  Resolve
Solution Provided "