Troubleshooting guides for issues that may arise in the process of configuring DRX.


Installation errors

  • Issues with installing the Visual C++ Redistributable Package for Visual Studio 2013 (hereafter VS2013 Redistributable Package) when installing DRX for Windows
    • Problem phenomenon 
      • Error installing "VS2013 Redistribution Package" that automatically adds after DRX installation
      • Cause: An inherent flaw in the VS2013 redistribution package.
    • Solution

      • Windows Server 2012 R2

        • Description: "VS2013 Redistribution Package" requires KB2883200 (Windows Update) for Windows Server 2012 R2.
        • Solution: Ensure that Windows Update KB2883200 is installed. If it is not installed, install it through Windows Update.
      • Windows Server 2008 R2 SP1
        • Explanation: Error 0x800b010a occurs.
          • [0AD8:05C0][2018-07-26T15:33:04]e000: Error 0x800b010a: Failed authenticode verification of payload: C:\ProgramData\Package Cache\.unverified\vcRuntimeMinimum_x64
            [0AD8:05C0][2018-07-26T15:33:04]e000: Error 0x800b010a: Failed to verify signature of payload: vcRuntimeMinimum_x64
            [0AD8:05C0][2018-07-26T15:33:04]e310: Failed to verify payload: vcRuntimeMinimum_x64 at path: C:\ProgramData\Package Cache\.unverified\vcRuntimeMinimum_x64, error: 0x800b010a. Deleting file.
        • Solution: Update Windows Update for additional ".NET Framework 3.5.1" entries.

Unable to start a resource

  • Failed to read settings due to UTF-8 with BOM file format
    • Problem phenomenon

      • Failed to read drx.conf

        DRX 로그
        E1120 16:37:02.690660 t42053 config] Failed to load [/opt/DRX/drx.conf]. /opt/DRX/drx.conf(1): '=' character not found in line
      • Failed to read BSR settings

        DRX 로그
        E1120 16:37:52.810044 t42132 config] Failed to get drbd configuration: Can't get drbd configuration. (exit_code: 2560)
        E1120 16:37:52.810068 t42132 config] Output: drbd.d/1/r0.res:1: Parse error: 'global | common | resource | skip | include' expected,
        E1120 16:37:52.810070 t42132 config] Output: but got '▒'
      • Cause: Failed to parse configuration file due to bill of materials information.
    • Solution

      • Centos 6, 7
        • Check the file's encoding with the file command.

          [root@drxdev1 test]# file r1.res
          r1.res: UTF-8 Unicode (with BOM) text, with CRLF line terminators
        • Open the file with vi, type the following, and save.
          :set nobomb
      • Windows
        • Open the file with notepad and change the encoding to 'ANSI' via 'Save As'.

Unable to connect

Because there are many possible reasons why a DRX connection might not be established, you should follow the order of the replication connection configuration procedure and check it carefully. The following configuration sequence is based on Linux and is the same for Windows

Network environment

  1. Verify that the bsr's IP and drx's IP are set in the node's firewall policy allowlist. If they are not enforced for the IP and port used by the resource, do the following
    1. Centos 6

      Add what you want to set to the /etc/sysconfig/iptables file.

      -A INPUT -p tcp -s \{source ip\} -d \{destination ip\} --dport \{Allowed Ports\} -j ACCEPT
    2. Centos 7

      firewall-cmd --permanent --zone=public --add-port=\{허용할 포트\}/tcp 
      firewall-cmd --reload
      firewall-cmd --zone=public --list-all
  2. Check the loopback ping
    1. If there is a ping response to the loopback address (127.0.0.1) but no ping response to the local IP address, there is a problem with the configuration of your network environment. In this case, you should contact your network administrator.

Version

  1. drbd : 8.4.8 or later
  2. drbd util : 8.9.10 or later
  3. Verify that the drbd kernel driver module is loaded with the lsmod | grep drbd command.

    1. [root@c65-3 build_files]# lsmod | grep drbd
      drbd                  374888  3 
      [root@c65-3 build_files]# 
  4. fsr: 1.2 or later

  5. bsr: all version availabl

Checking the DRX version

Ensure that the DRX version on the local node and the DRX version on the remote node are the same. Although DRX provides backward compatibility between versions, it is recommended that you configure with the same version of DRX whenever possible.

Check resource settings

  1. Check if the resource configuration file is saved in ANSI format or UTF8 format → UTF8 with BOM format is not supported.
  2. Check hostname settings: When changing the hostname, be careful about whether it has been applied correctly.
  3. Check whether individual ports are used per resource: Check that there is no duplicate use of ports.


BSR Configuration

  1. Change the resource configuration of the BSR to connect directly between the BSRs without interfacing with DRX to verify that the connection works.
  2. Verify with bsrsetup show that the ip loaded on the BSR is the same as the ip set in the resource file.
  3. Check whether wfc-timeout is set in the global entry. If not set, set the wfc-timeout value to 1.
  4. Add the value of ping-timeout to the "net" entry of the resource. The default value is 500ms, set it to 30 (3 seconds) to be generous.


DRX Configuration


  1. DRX 간 연결

    1. bsr의 리소스들을 모두 standalone상태로 변경 합니다: bsradm disconnect r0
    2. drx를 설치하고 drxsvc를 start한 상태에서 drx간의 연결을 확인합니다.  
    3. netstat 출력물에서 drx ip와 포트가 LISTEN/ESTABLISHE/TIME_WAIT인지 여부를 확인합니다.
    4. 정상적일 경우 리소스의 연결 상태는 bridged 상태 입니다.
      1. 이 때의 bsr 상태는 standalone 이며 drx 가 bsr과 연결하기 위한 상태는 connecting / waiting 상태로 전환됩니다. 
    5. 양노드의 drx의 상태가 bridging이라면 drx간에 연결을 시도하는 상태이며 일정시간이 지나도 변화가 없다면 WAN 구간 상의 연결을 먼저 점검해 봐야 합니다.
      1. icmp ping 은 보통 방화벽 정책에 의해 차단되어 있을 가능성이 있기 때문에 drxsim등을 통한 로컬과 원격간의 TCP 연결 가능여부를 확인합니다.
  2. bsr - drx 간 연결
    1. standalone이었던 bsr 리소스의 상태를 connecting상태로 변경한다. → bsradm connect 명령어로 상태를 변경 합니다.
      • cat /proc/kmsg/의 로그에서 리소스의 상태가 Connecting으로 변경되는지 확인합니다.
    2. 정상 상황일 경우 bsr과 drx가 연결되면 established 로 연결이 성립됩니다.
    3. 만약 bsr의 status가 connecting이고 연결이 성립되지 않는다면 netstat 출력물에서 bsr ip가 LISTEN상태인지 확인합니다. 
    4. local drx가 local bsr ip로 SYN_SENT를 시도하는지 확인합니다.
      1. TCP의 상태변경이 신속하게 바뀔 수 있기 때문에 netstat에 SYN_SENT 상태 출력이 파악되지 않을 수도 있습니다.
      2. netstat의 결과를 다음과 같은 스크립트 형태로 지속적으로 모니터링 합니다.

        $> while(true); do date; netstat -nap | grep 779 | sort -k 3; sleep 1; clear; done
        Thu Aug 23 08:51:23 PDT 2018
        tcp        0      0 192.168.100.3:35814         192.168.100.3:7792          ESTABLISHED -                   
        tcp        0      0 192.168.100.3:7791          0.0.0.0:*                   LISTEN      -                   
        tcp        0      0 192.168.100.3:7792          192.168.100.3:35814         ESTABLISHED 8033/drx            
        tcp        0      0 192.168.100.3:7793          192.168.100.2:60676         ESTABLISHED 8033/drx            
        tcp        0      0 192.168.100.3:7795          0.0.0.0:*                   LISTEN      8033/drx            
        tcp        0      0 192.168.100.3:7796          192.168.100.2:43684         ESTABLISHED 8033/drx            
        tcp        0      1 10.10.0.182:50460           31.1.1.2:7793               SYN_SENT    8033/drx            
        tcp        0      1 10.10.0.182:57966           31.1.1.2:7796               SYN_SENT    8033/drx            
        unix  3      [ ]         STREAM     CONNECTED     18779  2477/gconfd-2       
        unix  3      [ ]         STREAM     CONNECTED     20779  2512/gnome-panel    
        
        
    5. bsr과 drx가 연결되면 netstat 출력물에서 리소스의 bsr ip와 drx의 ip가 eastablished 상태가 되는지 확인합니다.
    6. drx 로그에 실패(Ex. connection refuse)에 대한 로그가 있는지 확인합니다.
  3. 로그 수집
    1. cat /etc/sysconfig/network-scripts/ifcfg-* 명령어로 출력되는 결과물을 수집합니다.
    2. /var/log/messages
    3. service iptables status
    4. ip a 명령어로 출력되는 결과물



VIP 연결 불가

만약 VIP 를 사용하는 Active/Standby 양 노드에서 동일한 VIP 를 통해 소켓 Bind 가 수행될 경우 양노드 간의 통신 간섭이 발생할 수 있습니다. 따라서 DRX를 VIP로 연동(SDR, MDR 등)할 경우 대기 노드의 DRX는 반드시 기동을 중지해야 하고, 대기노드로 페일오버 후 리소스를 up 하기 이전에 DRX 를 기동시켜야 연결이 원활하게 수행될 수 있습니다.